# Purific Australia > Purific Australia provides simple, reliable ultrapure water systems for pathology labs\. 30 years of expertise and assigned engineers for accurate results\. Generated by Yoast SEO v28.3, this is an llms.txt file, meant for consumption by LLMs. ## Pages - [Purific – Terms \& Condition](https://purific.com/purific-terms-condition) - [Contact Purific](https://purific.com/contact-us) - [Members](https://purific.com/members-2) - [Password Reset](https://purific.com/password-reset-2) - [Account](https://purific.com/account-2) ## Posts - [4x Ways To Remineralize RO Water](https://purific.com/how-to-remineralize-ro-water) - [Laboratory Water Purification Systems: The Complete Selection Guide](https://purific.com/laboratory-water-purification-systems) - [Types of Lab Water Explained: ASTM, ISO, and CLSI](https://purific.com/types-of-lab-water) - [The Lab Safety Rules You Can't Afford to Skip](https://purific.com/lab-safety-rules) - [Types of Water Explained: What Each One Means for Your Health](https://purific.com/types-of-water) ## Products - [Pretreatment Platform](https://purific.com/shop/pretreatment-platform): \
Centralises pressure boosting for every connected Analytica unit, keeping supply consistent even when two or more systems are drawing at once\.\
\Regulates feed pressure before it splits to each unit's RO stage, so one Analytica's usage never affects the pressure reaching another\.\
\A dedicated carbon stage conditions the feed ahead of the manifold, which then splits a single supply into balanced outlets for each Analytica, replacing the need to fit a separate Pretreatment Unit \(CPU\) to every individual system\.\
\An optional prefiltration housing can be added ahead of the carbon stage for sites with higher sediment loads, protecting carbon media and downstream filters from premature fouling\.\
\Built for laboratories running two or more Analytica 100 or Analytica 100 Pro systems from a shared feed line\. Instead of fitting a Carbon Pretreatment Unit to every individual analyser, the Pretreatment Platform consolidates booster, regulation and pretreatment into a single shared system, so each connected unit starts from the same conditioned, evenly pressured supply\.\
\A single Pretreatment Platform can feed two or more Analytica 100 or Analytica 100 Pro systems, reducing duplicated plumbing and giving every unit the same starting water quality\.\
\Add the prefiltration housing only where feed water conditions call for it, keeping the base platform compact for sites with cleaner mains supply\.\
\Our team advises on integrating the Pretreatment Platform with your existing lab plumbing and multiple Analytica installations\.\
\Consumables and servicing are supported locally, so uptime doesn't depend on an overseas freight schedule\.\
\\* Recommended for sites running two or more Analytica systems\. Prefiltration housing is available as an optional add on for sites with higher sediment loads\. \
\A secure fitting lid closes the drum against dust, airborne particulates, and evaporation, so deionised water stored inside keeps the same quality it had the moment it left your purification system\.\
\Constructed from food grade polypropylene, a material naturally resistant to a wide range of chemicals and inert against the water it holds\. Nothing leaches in, nothing leaches out\.\
\Two integrated handles keep the drum manageable to lift and carry once filled, without needing extra equipment for short distance moves around the lab or storeroom\.\
\A compact, uniform shape allows drums to stack cleanly when empty, keeping storeroom space efficient as your stock grows\.\
\Buy 20 or more drums and the price drops to $10 each, ideal for stocking up across multiple storage points or restocking in bulk\.\
\The same airtight seal and inert material that protect DI water also suit general bulk dry storage\. Many customers use these drums for pet food, working animal feed, and as a base for building gravity or treadle style feeders, where a tight seal keeps contents fresh and pest free\.\
\This item is available for collection from Mosman\. Please arrange a pickup time after purchase\.\
\Shipping and delivery are not offered on this product\. Collection in person is the only fulfilment option\.\
\\* Price and product reference to be confirmed\. Local pickup from Mosman only, no shipping available on this item\.\
\Removes the chlorides, calcium and dissolved minerals that damage hot water paths, boilers and heat exchangers in autoclave and thermal washer equipment\.\
\Eliminates the ongoing cost, storage space and hassle of buying bottled distilled or demineralised water for your autoclave\.\
\Compact footprint designed for practice utility rooms, not laboratory floor plans\.\
\Removes chlorides, calcium and manganese salts that damage hot water paths, boilers and heat exchangers in autoclave and thermal washer equipment, extending instrument and equipment life\.\
\Prolongs membrane life and maintains consistent output without manual intervention\.\
\Standard tank with optional upgrade for practices running higher volume sterilisation cycles or multiple chairs\.\
\In December 2023, AS 5369:2023 replaced the previous standard covering water quality for reprocessing reusable medical devices, including dental instruments\. The ADA's own infection control guidelines have referenced it directly since February 2024\.\
\The current standard introduced a new endotoxin testing requirement for final rinse water that did not exist previously\. Practices should check their current compliance position\.\
\Legal installation requires a WaterMark certified product\.\
\Designed, manufactured and stocked in Australia, meaning fast turnaround on parts and no waiting on international freight\.\
\Direct access to Purific's engineering team for installation guidance, maintenance and technical advice\.\
\Because keeping the surgery running should not cost extra\.\
\\* Full technical specifications and pricing are being finalised\. Register your interest below and our team will follow up directly\.\
\request a quote\
\Delivers consistent, high\-purity water meeting Special Reagent Grade requirements for laboratory and clinical analyser applications\. It ensures every test result is built on a reliable, uncontaminated foundation\.\
\Combines cation and anion exchange resin in a single cartridge\. This dual\-action approach efficiently strips trace ionic impurities in a single pass, simplifying your purification train without sacrificing performance\.\
\Designed for sensitive analytical workflows where ionic contamination produces errors\. The I\-600 guards against the trace impurities that compromise immunoassay, haematology, and biochemistry analysers\.\
\Single\-handed, tool\-free cartridge replacement in seconds\. No spanners, no special skills, no system shutdown; the cartridge clicks out and the replacement clicks in\.\
\Air is purged automatically the moment the new cartridge is seated\. No manual priming cycle\. No waiting\. The system returns to full purification operation immediately\.\
\Cartridge maintenance has zero impact on laboratory workflow\. Replace the I\-600 mid\-run without shutting down your analyser feed or interrupting critical sample processing\.\
\At 85mm × 80mm head and 570mm length, the I\-600 fits within standard Purific system housings and ships in cases of four; minimising storage footprint\.\
\Complete dimensional and connection reference for facility planning and procurement\.\
\Positively charged ions including calcium, magnesium, sodium, and heavy metals are captured by the cation exchange resin component\. This stage eliminates the primary source of resistivity degradation in laboratory water systems\.\
\Negatively charged species including chloride, sulphate, nitrate, and bicarbonate are simultaneously removed\. Operating in tandem with cation exchange, this produces a deeply deionised effluent in a single pass\.\
\The resin formulation is engineered for stable output from first use to end\-of\-life\. Water quality does not degrade gradually\. The cartridge delivers consistent purity until resin capacity is exhausted\.\
\Supplied in boxes of four, the I\-600 is designed for easy stock management\. A single order keeps your laboratory covered, reducing procurement frequency and administrative overhead\.\
\Our Australian service team covers every major city with certified technicians\. Expert support is available 24 hours a day, 365 days a year\.\
\The PIMO I\-600 is a factory\-specified consumable for Purific Analytica systems including the Analytica 100 Pro\. Contact our team to confirm compatibility with your installation\.\
\\*Performance data based on standard laboratory supply water\. Cartridge service life is dependent on feed water ionic load and throughput volume\. Consult Purific technical support for site\-specific service interval guidance\.\
\Produces 18\.2 MΩ/cm resistivity water that exceeds Clinical Laboratory Reagent Water standards\. It ensures every test result is a definitive fact\. \
\A dedicated production rate of 80–100L per hour keeps pace with the most demanding clinical schedules\. Pure water is available the moment your analyser calls for it\. \
\Integrated TFC High Rejection membranes provide up to 99% salt rejection\. This core technology ensures a reliable feed for the ultra\-purification stages\. \
\A 3mm powder\-coated aluminium chassis provides a rugged, corrosion\-resistant home\. Engineered to withstand the rigours of a high\-traffic laboratory\. \
\Includes a high\-quality Reverse Osmosis pressure booster pump manufactured by Grundfos in Denmark\. Quiet, reliable, and designed for continuous operation\. \
\The system grows alongside your laboratory\. Add future units seamlessly to meet rising demand without overhauling your existing infrastructure\. \
\Maximize your floor plan\. The Analytica can be wall\-mounted directly to a backboard or configured as a freestanding frame unit\. \
\The optional Carbon Pretreatment Unit features three 1 Micron particulate filters\. Location flexible to fit any laboratory layout\. \
\A 0\.2μm disposable microporous membrane removes all particles and micro\-organisms\. Every filter is integrity tested for quality assurance\. \
\Integrated UV TOC reduction and sanitisation units eliminate organic contaminants, keeping the entire distribution loop biologically pure\. \
\Smart resistivity monitoring triggers a water purity quality alarm the moment water deviates from the required reagent standards\. \
\High\-purity mixed\-bed resin columns maintain peak quality\. Designed for rapid exchange to minimize downtime during maintenance\. \
\Our Australian service team covers every major city with certified technicians\. Expert support is available 24 hours a day, 365 days a year\. \
\\* Production capacity is dependent on the quality and quantity of supply water\. Typical performance is 80\-100L/h based on Australian potable water standards\. \
\request a quote\
\download technical data\
\